How to Install 25D 360 MAX HIFU Machine ?
1. Steps to add water to cartridges
36RS Cartridge

Add 50ml of purified water into 36RS cartridge

Apply the sealing sticker to ensure no water leaks out.
15RS Cartridge

Add 80ml of purified water into 15RS cartridge

Apply the sealing sticker to ensure no water leaks out.
18RS Cartridge

Add 200ml of purified water into 18RS cartridge

Apply the sealing sticker to ensure no water leaks out.
2. Steps to install 25D 360 MAX HIFU Machine


Install handle bracket


Align the 36RS Cartridge with the handle before insertion and installation.


Place the 36RS handle onto the bracket, then connect the cable to the plug.


Press and hold the gold button, then pull out the cartridge. You may replace cartridges of different penetration depths.


Align the 18RS Cartridge with the handle before insertion and installation.


Place the 18RS handle onto the bracket, then connect the cable to the plug.


Press and hold the gold button, then pull out the cartridge. You may replace cartridges of different penetration depths.


Align the 15RS Cartridge with the handle before insertion and installation.


Place the 15RS handle onto the bracket, then connect the cable to the plug.


Press and hold the gold buttons on both sides of the 15RS handle, then pull out the ink cartridge. You can replace the cartridge with one of different penetration depths.


Install the foot switch